SJOC Trunk System LED II PAR-L


Beskrivelse

5-pole electrical connection a) Three-phase operation Use of the 3-phase system allows TRUNK to be installed in very long uninterrupted lines, making it an ideal solution for large buildings. The 3-phase system, by utilising the third phase as a control line, also allows for any number of individual luminaires to be switched off during periods of inactivity while some remain switched on to provide a required minimum illumination. b) Two-phase operation + emergency lighting When using only two phases, it is possible to use the spare phase conductor for other things such as emergency lighting.

7-pole electrical connection This variant offers all of the above-mentioned advantages in addition to the possibility of including lighting control (LMS). 7-pole connection is necessary for installation in lighting systems determined for the following uses: a) Three-phase operation + LMS Further to allowing for continuous connection in long uninterrupted lines and basic switching control, the extra connectors can be used for connection of dimmable electronic control gears. b) Two-phase operation + emergency lighting + LMS 7-pole wiring enables the implementation of emergency lighting while still offering free connectors for dimmable electronic control gears.

9-pole electrical connection 9-pole connection allows for almost unlimited inclusion of other systems in addition to standard operation, emergency lighting and an LMS. 9-pole connection is necessary for installation in lighting systems determined for the following uses: a) Three-phase operation + emergency lighting + LMS Allows for full three-phase operation in addition to connection for emergency lighting and an LMS. In the case of DALI control, this broadens control possibilities. b) Two-phase operation + emergency lighting + emergency lighting /loud speaker system / other separated phase circuit The additional two connectors can be used for connection of a wide range of other circuits such as a second, independent emergency lighting system, the feeding of load speakers (which can be included in the TRUNK SYSTEM), or any other separated phase circuit.


Varespecifikation

Vare nr.

 

Cri

Ra

Lumen

lm

Effekt

W

Farve

K

TRUNK II PLL

 

> 80

3750 lm

32 W

3000

TRUNK II PLL 

 

> 90

3850 lm

32 W

4000

TRUNK II PLL

 

> 80

6150 lm

52 W

3000

TRUNK II PLL 

 

> 90

6350 lm

52 W

4000

TRUNK II PLL TRD

 

> 80

3600 lm

32 W

3000

TRUNK II PLL TRD

 

> 90

3700 lm

32 W

4000

TRUNK II PLL TRD

 

> 80

5900 lm

52 W

3000

TRUNK II PLL TRD

 

> 90

6100 lm

52 W

4000